Online inquiry

搜索信息

Product
Home > PRODUCTS
GGJ low-voltage reactive power intelligent compensation device Price:¥

Online inquiry
Detailed content Specification parameter Product packaging

product description

GGJ low-voltage reactive power intelligent compensation device can effectively improve the power factor of electrical loads, reduce line losses, and increase the actual load capacity of transformers. It has significant energy-saving effects. At the same time, the use of specific reactors in the system can also effectively prevent harmonics. Amplify and effectively absorb most of the harmonic currents, so that the total harmonic voltage distortion rate limit and each harmonic current content limit comply with national standards, achieving the purpose of harmonic control. It introduces microcomputer control to implement intelligent tracking and compensation of reactive power. It has a reasonable structure and advanced technology. It is suitable for low-voltage power grids such as substations of industrial and mining enterprises, production workshops and civil buildings. It is especially suitable for frequent changes in load and reactive power. Transmission and distribution system with unstable power. It has a significant effect on improving power factor, reducing reactive power loss and improving power supply quality. It is a new generation of energy-saving product.

Model and its meaning

 

main feature

1. It is controlled by an intelligent controller and has complete functions. Reliable performance, automatic compensation mode; can increase the power factor to above 0.9;
2. Real-time display of grid power factor, display range: lag (0.00-0.99), lead (0.00-0.99);
3. With over-voltage and over-harmonics , over-compensation, system failure, phase loss, overload and other comprehensive protection functions:
4. Memorize the set parameters, the system will not lose parameters after a power outage. After the power grid returns to normal, it will automatically enter the operating state without personnel on duty;
5. Split-phase compensation or mixed compensation can be adopted according to the load balance of the power grid;
6. It has strong anti-interference ability and can withstand interference pulses with an amplitude of 2000V directly input from the power grid, which is higher than the national professional standard.

GGJ technical parameters

project

parameter


Rated voltage

0.38-0.66kV

Rated frequency

50Hz

Rated Capacity

1-600kvar

Applicable voltage range

(0.85-1.1) times rated voltage

***Allow current

1.3 times rated current

Control loop

1-16 circuits

turnaround time

1-150S/time, adjustable

Way of working

Automatic, continuous operation

The main function

1. Real-time measurement and hourly recording of the three-phase voltage, current, frequency, active power, reactive power, power factor, active energy, and reactive energy on the low-voltage side of the transformer; the total distortion rate of voltage and current and the 2nd to 25th harmonics Wave content;
2. It has RS-232 and RS-485 interfaces, which can be used for handheld computer data transcription, and can also realize wireless meter reading, device testing, parameter setting and real-time measurement data and record data reading through remote communication functions;
3. Data analysis function: It can analyze, process and statistically query operating load data; comprehensively analyze power supply quality, calculate voltage qualification rate, power supply load rate, reliability rate and maximum load rate; query power factor, active power and Reactive power; draw curves of each phase voltage, current, power factor, etc.; print comprehensive analysis and statistics


© 2024 Fujian Dianchuang Intelligent Technology Co., Ltd  All Rights Reserved.   备案号:闽ICP备2024049565号-1 腾云建站仅向商家提供技术服务